Share:


Vibration Separator GY-200

Directions 1
  • Prior to operate the separator, ensure all the components are fastened, no broken on the sieves, no damage on the machine body, electrical cables are connected properly (do not use a knife switch), and three phase power supply is ready.
  • Please check whether the machine model and specification are the same as your order. Power supply is the same as shown on the machine plaque. (Tolerance for voltage is + / - 10 %)
Preparation
  • Place screen pots with required mesh onto the machine base sequentially.
  • Feed raw material on the top screen pot, and then close the lid.
  • Adjust the height of telescope poles accordingly and fasten the telescope knobs. Tighten the two black screen pot holding knobs to secure the lid.
Operation
  • When power supply is on, the red power indicator comes on.
  • Set the timer ( between 0 – 30 minutes ).
  • Switch the start button, the green indicator comes on and machine starts working until the setting timing is up.
Directions 2
  • Check the electrical components and all moving parts regularly during operation. Adjust if needed.
  • This machine is guaranteed for one year under normal operating condition. Please contact our offices or distributors should any irregularity arise during the one-year warranty period. Do not under any circumstances attempt to make any repairs or replacements.

Configuration

  • Screen pot holding knob.
  • Telescope pole.
  • Screen pot.
  • Ventilation hole.
  • Shock absorption rubber.
  • Power.
  • Telescope knob.
  • Machine base.
  • Timer.
  • Power.
  • Indicator.
Specification
Motor Voltage Frequency Speeds (R.P.M)
0.3 HP Single phaee: 110 V / 220 V
Three phase: 220 V / 380 V / 415 V
50Hz / 60Hz 1440 / 1720

Maintenance

  • Turn off power supply when the machine is not in use for an extended period of time.
  • Clean the screen pots after operation, so they will be ready for use next time.
  • Do not splash water on the machine to avoid current leakage.
  • Turn the machine off immediately in the event of unusual noises and inspect for blockage or other irregularities.
  • Always ensure the black knobs are securely tightened before operation.